  acdc specification 560 watts ? rugged design for industrial applications ? up to 89% efficiency ? full power to +60 c ? wide adjustment range ? dc ok 24 v models ? dc standby versions ? 3 year warranty dnr series input input voltage ? 90-264 vac, 120-375 vdc (dnr05/10/18) 85-264 vac, 90-375 vdc (dnr30/60) input frequency ? 47-63 hz input current ? see tables inrush current ? 5-18 w: 10/18 a at 115/230 vac 30 w: 20/40 a at 115/230 vac 60 w: 30/60 a at 115/230 vac power factor ? en61000-3-2, class a earth leakage current ? 0.8 ma max input protection ? internal fuse t2a, 250 vac fitted in line output output voltage ? see tables output voltage trim ? see tables initial set accuracy ? 1% minimum load ? no minimum load required start up delay ? <1 s (may increase at low temperature extremes) start up rise time ? <150 ms hold up time ? 30/130 ms at 115/230 vac (dnr05) 25/100 ms at 115/230 vac (dnr10) 20/75 ms at 115/230 vac (dnr18) 20/30 ms at 115/230 vac (dnr30) 20/30 ms at 115/230 vac dnr60) line regulation ? 5-18 w: 1.0% max 30-60 w: 0.5% max load regulation ? 5-18 w: 2.0% max 30-60 w: 0.5% max parallel operation ? redundancy module dpm10 available for load currents up to 10 a (not with standby system), contact sales transient response ? 4% max deviation recovery to within 1% in 2 ms for a 50% load change ripple & noise ? 50 mv pk-pk, 20 mhz bandwidth (may increase at low temperature extremes) overvoltage protection ? output clamps at 120-145% vnom, auto recovery overload protection ? 110-145% constant current (dnr05-18) 105-150% power limited (dnr30/60) short circuit protection ? power limited, auto recovery temperature ? 0.03%/c coefficient xppower.com general efficiency ? see tables isolation ? 3000 vac input to output, 1500 vac input to ground, 500 vac output to ground switching frequency ? 132 khz typical, 55-90 khz (dnr60) signals ? dc on indicator led green: all models dc low indicator led red: 5-18 w models dc ok: 24 v 30-60 w models dc ok: all standby models mtbf ? 800 khrs typical bellcore, issue 6 at +40 c, gb (dnr05/10/18), 530 khrs typical bellcore, issue 6 at +40 c, gb (dnr30/60) din rail ? compatible with ts35/7.5 or ts35/15 environmental operating temperature ? -20 c to +70 c (dnr05/10/18) -40 c to +70 c, start up at -35 c (dnr30/60), all units derate linearly from 60 c (see derating curves) cooling ? convection-cooled with 25mm free space all sides operating humidity ? 20-95% rh, non-condensing storage temperature ? -25 c to +85 c (dnr05/10/18) -40 c to +85 c (dnr30/60) shock ? 15 g, 11 ms, x, y & z axis, 3 shocks/axis in both directions vibration ? 2 g, 10 hz to 500 hz, along x, y & z axis, 60 mins/axis, mounted on rail emc & safety emissions ? en55022, level b conducted & radiated harmonic currents ? en61000-3-2, class a voltage flicker ? en61000-3-3 esd immunity ? en61000-4-2, level 4, perf criteria a radiated immunity ? en61000-4-3, level 3, perf criteria a eft/burst ? en61000-4-4, level 4, perf criteria a surge ? en61000-4-5, installation class 3, perf criteria a conducted immunity ? en61000-4-6, level 3, perf criteria a magnetic field ? en61000-4-8, level 4 perf criteria a dips & interruptions ? en61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms perf criteria a, b, b safety approvals ? en60950-1, ul508 pollution degree 2, ul1310 class 2 power recognised, see note 3 & ratings table, ul60950-1 overvoltage category ii, ul508 overvoltage category iii, dnr30 & dnr60: semi f47 ansi/isa 12.12.01. class 1, division 2 groups a,b,c and d
acdc dnr0560 models and ratings output voltage input current (typ.) output voltage trim output current efficiency (typ.) model number 115 vac 230 vac 5 v 0.12 a 0.08 a 4.50-5.75 v 1.000 a 69% dnr05us05 (1) 12 v 0.12 a 0.08 a 10.80-13.80 v 0.420 a 72% dnr05us12 (1) 15 v 0.12 a 0.08 a 13.50-17.25 v 0.340 a 72% dnr05us15 (1) 24 v 0.12 a 0.08 a 21.60-28.80 v 0.210 a 72% dnr05us24 (1) 5 v 0.20 a 0.13 a 4.50-5.75 v 2.000 a 73% dnr10us05 (1) 12 v 0.20 a 0.13 a 10.80-13.80 v 0.840 a 75% dnr10us12 (1) 15 v 0.20 a 0.13 a 13.50-17.25 v 0.670 a 76% dnr10us15 (1) 24 v 0.20 a 0.13 a 21.60-28.80 v 0.420 a 76% dnr10us24 (1) 5 v 0.36 a 0.21 a 4.50-5.75 v 3.000 a 75% dnr18us05 (1) 12 v 0.36 a 0.21 a 10.80-13.80 v 1.500 a 77% dnr18us12 (1) 15 v 0.36 a 0.21 a 13.50-17.25 v 1.200 a 77% dnr18us15 (1) 24 v 0.36 a 0.21 a 21.60-28.80 v 0.750 a 77% dnr18us24 (1) 5 v 0.56 a 0.33 a 5.00-5.50 v 6.000 a 79% dnr30us05 (1,3,4) 12 v 0.56 a 0.33 a 12.00-14.00 v 2.500 a 84% dnr30us12 (1,3,4) 24 v 0.56 a 0.33 a 24.00-28.00 v 1.250 a 86% dnr30us24 (1,3,4) 48 v 0.56 a 0.33 a 48.00-55.00 v 0.625 a 86% DNR30US48 (1,3,4) 5 v 1.10 a 0.59 a 5.00-5.50 v 10.000 a 79% dnr60us05 (1,3,4) 12 v 1.10 a 0.59 a 12.00-14.00 v 5.000 a 86% dnr60us12 (1,3,4) 24 v 1.10 a 0.59 a 24.00-28.00 v 2.500 a 89% dnr60us24 (1,3,4) 48 v 1.10 a 0.59 a 48.00-55.00 v 1.250 a 89% dnr60us48 (1,3,4) notes 1. add suffix -s for spring clamp connection option. 2. 30-60 w models are suitable for battery-charging applications. 3. approved to ul1310, but 5 & 12 v not class 2 power recognised. 4. semi f47 compliant. derating curves dnr0518 w models dnr3060 w models -40 0 10 20 30 40 50 60 70 20 40 60 80 100 0 ambient temp (?c) load (%) -20 0 10 20 30 40 50 60 70 20 40 60 80 100 0 load (%) ,
acdc 5 4.53 (115.0) 1.59 (40.5) 3.60 (90.0) ac input dc output on 13 1 voltage trim -v -v +v +v dc ok nl dnr0560 dnr30/60 connections conn pin designation ac input 1 ground 2 neutral 3 line dc output 1 dc ok* 2 positive 3 positive 4 negative 5 negative mechanical details * 24 v and standby models only. 4.53 (115.0) 0.89 (22.5) 1 2 3.48 (88.5) 3 dc output dc lo on ac input voltage trim 1 -v +v nl notes 1. all dimensions in inches (mm). 2. weight 0.33 lb (150 g) approx. 3. tolerance: 0.02 (0.5) maximum. 4. connection screw maximum torque: input: 9 lbs-in (1.0 nm), output: 5.5 lbs-in (0.6 nm) notes 1. all dimensions in inches (mm). 2. weight 0.8 lb (350 g) approx. 3. tolerance: 0.02 (0.5) maximum. 4. connection screw maximum torque: input: 9 lbs-in (1.0 nm), output: 5.5 lbs-in (0.6 nm) dnr05, 10, 18 connections conn pin designation ac input 1 ground 2 neutral 3 line dc output 1 positive 2 negative dnr05/10/18 w models 30/60 w models
21-jan-11 acdc standby versions dnr0560 +v -v -v dc ok e.g. in4001 relay control d1 load +v 5 ac input dc output on 13 1 voltage trim -v -v +v +v dc ok nl lead acid battery fuse coil output set voltages for standby versions model (1) voltage current dc ok signal off efficiency dnr30us12 # 13.6 v 2.20 a 10.30-11.30 v 84% dnr30us24 # 27.2 v 1.10 a 21.10-22.10 v 86% DNR30US48 # 54.5 v 0.55 a 42.70-43.70 v 86% dnr60us12 # (2) 13.6 v 4.40 a 10.30-11.30 v 86% dnr60us24 # 27.2 v 2.20 a 21.10-22.10 v 89% dnr60us48 # 54.5 v 1.10 a 42.70-43.70 v 89% dcok n/o n/c common r l > 700 -vout coil coil dcok 22 k 0.5 w 5.1 v 0.3 w -vout dc ok standard on 24 v models, 30-60 w only. example using external relay to create volt-free contact example using external components to create ttl signal output good = 24 v output not good = 0 v dnr30/60 connection for dc standby system applications dnr30/60 connections conn pin designation ac input 1 ground 2 neutral 3 line dc output 1 dc ok 2 positive 3 positive 4 negative 5 negative notes notes maximum current drain from battery by psu when inactive 22 ma 1. with ac in, unit provides power to the load and to charge the battery. the dc ok signal acts by sensing a voltage on +v and holds the relay closed. 2. with loss of ac in, battery voltage is present on +v. dc ok signal holds the relay closed. battery supplies power to the load. 3. as the battery discharges, its voltage falls. when this falls below the level shown in the table below the dc ok signal switches off to allow the relay to open to disconnect and protect the battery. 1. suffix # indicates standby version. 2. not ul1310 approved. 30/60 w models


▲Up To Search▲   

 
Price & Availability of DNR30US48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X